MÁY HÚT BỤI AMANO VNA-SDN Series |
|
| Thương hiệu: AMANO | |
| Giá bán: Liên hệ | |
MÁY HÚT BỤI AMANO VNA-SDN Series
FULFILLING SAFETY MEASURES.DUST COLLECTOR FOR EXPLOSIVE AND FLAMMABLE DUST.
Material: Antistatic Tetron Felt + Aluminum + Earth
Surface treatment: Metal wire net weaving
Corresponding models: VNA-SDN/DN
Application: electrification characteristic dust
Others: Aluminum sheet and Earth
Finefil Antistatic filter is avilable
Dust explosions occur when the 3 conditions of “oxygen”, “Dust concentration higher than explosion threshold”, and “minimum ignition energy” are all present. If even just 1 of these conditions can be eliminated then dust explosions can be prevented. So the crucial point in preventing explosions is eliminating oxygen or sources of sparks.
Static electricity will make spark and could be ignition energy of dust explosion. Anti-electrostatic woven plate filter employs metal thread is woven into polyester technology and the filter has a strong and long time antistatic effect and reduces the possibility of generating spark cause by static electricity.![]()
Countermeasures against the problem of a dust explosion caused by static electricity are indispensable. The antistatic coating Conductive paint is effective in preventing static electricity and noise by painting on metal and plastic. The conductive paint prevents the spark inside the dust collector and dust explosion.![]()
Explosion pressure diffusion port is designed to be the “weak” area of the dust collector body, an Explosion pressure diffusion port opens when predetermined pressures are reached inside the collector, allowing the excess pressure and flame front to exit to a Explosion pressure diffusion port. It is designed to minimize damage to the dust collector and prevent it from blowing up in the event of a deflagration, thereby reducing the safety hazard.
| MODEL | KST VALUE | PMAX | |
|---|---|---|---|
| VNA-30SDN | 700 | 11.5 | |
| VNA-45SDN | 700 | 11.5 | |
| VNA-60DN | 300 | 11.0 |
The above Kst and Pmax value was covered calculated based on “Japan Explosive pressure discharge device technical guidelines(Revised version)NllS-TR-No.38(2005) in incorporated agency industrial safety institute laws. The above figures are for standard equipment. Please evaluate your target dust for explosion potential (option: dust powder explosion evaruation service are available)
| PARTICULAR | UNIT | VNA-30SDN | VNA-45SDN | VNA-60DN | |
|---|---|---|---|---|---|
| Power Supply | Volt | 220 | 220 | 220 | |
| Frequency | Hz | 60 | 60 | 60 | |
| Phase | 3P | 3P | 3P | ||
| Output | kw/hp | 1.5/2 | 2.2/3 | 3.7/5 | |
| Max Airflow | m³/min | 25 | 40 | 55 | |
| Max. Static Pressure | kPa | 2.55 | 2.63 | 2.64 | |
| Filter Area | m² | 9.0 | 13.5 | 18.0 | |
| Suction Port Ø | mm | 150 | 200 | 200 | |
| Dimension (WxDxH) | mm | 1020x1253x1754 | 1355x1328x1821 | 1546x1396x2055 | |
| Weight | kg | 340 | 400 | 460 |
Copyright © 2021 Công ty Cổ phần YHB ECO VINA.
Giấy chứng nhận đăng ký kinh doanh số 0107816087, cấp ngày 24/04/2017 bởi Sở Kế hoạch và Đầu tư TP. Hà Nội.
Địa chỉ đăng ký trụ sở chính: Tổ 4, Thị Trấn Quang Minh, Huyện Mê Linh, TP. Hà Nội, Việt Nam
Copyright © 2021 Công ty Cổ phần YHB ECO VINA.
Giấy chứng nhận đăng ký kinh doanh số 0107816087, cấp ngày 24/04/2017 bởi Sở Kế hoạch và Đầu tư TP. Hà Nội.
Địa chỉ đăng ký trụ sở chính: Tổ 4, Thị Trấn Quang Minh, Huyện Mê Linh, TP. Hà Nội, Việt Nam